Test Code RSMPU Monoclonal Protein Screen, Random, Urine
Ordering Guidance
The use of a random urine specimen is sufficient for identifying the presence or absence of monoclonal proteins, but a 24-hour specimen is preferred for quantitating and monitoring the abnormality. See SMPU / Monoclonal Protein Screen, 24 Hour, Urine.
Shipping Instructions
Refrigerate specimen after collection and send refrigerated.
Specimen Required
Supplies: Urine Container, 60 mL (T313)
Submission Container/Tube: Plastic, 60-mL urine bottle
Specimen Volume: 50 mL
Collection Instructions:
1. Collect random urine specimen.
2. Aliquot between 30 mL and 50 mL of urine into a plastic, 60 mL urine bottle.
Useful For
Identifying monoclonal gammopathies using random urine specimens
Profile Information
Test ID | Reporting Name | Available Separately | Always Performed |
---|---|---|---|
MPTRU | M-protein Mass-Fix, Random, U | No | Yes |
RPTU2 | Protein/Creatinine Ratio, Random, U | Yes, (RPTU1) | Yes |
Reflex Tests
Test ID | Reporting Name | Available Separately | Always Performed |
---|---|---|---|
RPEU | Protein Electrophoresis, Random, U | No | No |
Special Instructions
Method Name
RPTU2: Turbidimetry/Enzymatic Colorimetric Assay
RPEU: Agarose Gel Electrophoresis
MPTRU: Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry (MALDI-TOF MS)
Reporting Name
M-protein Screen, Random, USpecimen Type
UrineSpecimen Minimum Volume
30 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Urine | Refrigerated (preferred) | 14 days | |
Frozen | 5 days | ||
Ambient | 24 hours |
Reject Due To
All specimens will be evaluated at Mayo Clinic Laboratories for test suitability.Clinical Information
Urine proteins can be grouped into 5 fractions by protein electrophoresis:
-Albumin
-Alpha-1-globulin
-Alpha-2-globulin
-Beta-globulin
-Gamma-globulin
One or more quantifiable monoclonal proteins may be present and reported as M spike
The urine total protein concentration, the electrophoretic pattern, and the presence of a monoclonal immunoglobulin light chain may be characteristic of monoclonal gammopathies such as multiple myeloma, primary systemic amyloidosis, and light-chain deposition disease.
The following algorithms are available:
Reference Values
CREATININE:
≥18 years old: 16-326 mg/dL
Reference values have not been established for patients younger than 18 years of age.
PROTEIN/CREATININE RATIO:
≥18 years: <0.18 mg/mg creatinine
Reference values have not been established for patients younger than 18 years of age.
ELECTROPHORESIS, PROTEIN
The following fractions, if present, will be reported as mg/dL:
-Albumin
-Alpha-1-globulin
-Alpha-2-globulin
-Beta-globulin
-Gamma-globulin
No reference values apply to random urines.
MASS-FIX M-PROTEIN ISOTYPE
M-protein Isotype MS:
No monoclonal protein detected
Flag M-protein Isotype MS:
Negative
Day(s) Performed
Monday through Friday
Report Available
4 to 6 daysPerforming Laboratory
Mayo Clinic Laboratories in RochesterTest Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.CPT Code Information
84156
82570
84166 Electrophoresis, protein (if appropriate)
0077U
Forms
If not ordering electronically, complete, print, and send a Renal Diagnostics Test Request (T830) with the specimen.