Sign in →

Test Code QFT4 QuantiFERON-TB Gold Plus, Blood


Ordering Guidance


This test is not recommended for use for diagnosis of active tuberculosis (TB) infection. It can be used as an aid to detect latent TB infection.



Specimen Required


Supplies:

-QuantiFERON-TB Gold Plus Collection Kit (T794)

-QuantiFERON-TB Gold Plus HIGH ALTITUDE Collection Kit (T795)

Collection Instructions:

1. Special collection, incubation, and centrifugation procedures must be followed.

2. For blood collection options (1-tube collection or 4-tube collection) and specimen transport instructions, see Mycobacterium tuberculosis Infection Determination by Quanti-FERON-TB Gold Plus Collection and Processing Instructions (T688).


Useful For

Indirect test for Mycobacterium tuberculosis infection, to be used in conjunction with risk assessment, radiography, and other medical and diagnostic evaluations

 

This test is not recommended for use for diagnosis of active tuberculosis infection.

Method Name

Chemiluminescence Immunoassay (CLIA)/Enzyme-Linked Immunosorbent Assay (ELISA) as appropriate

Reporting Name

QuantiFERON-Tb Gold Plus, B

Specimen Type

Whole blood

Specimen Minimum Volume

4 mL: 1 mL per tube (4 tubes)

Specimen Stability Information

Specimen Type Temperature Time Special Container
Whole blood Refrigerated 28 days QTBKIT

Reject Due To

Specimen submitted not following kit guidelines Reject
Gross hemolysis Reject
Gross lipemia Reject
Gross icterus Reject

Clinical Information

Latent tuberculosis infection (LTBI) is a non-communicable, asymptomatic condition that persists for many years in individuals and may progress to active tuberculosis disease, particularly in patients who are immunosuppressed. The primary goal for diagnosis of LTBI is to initiate medical treatment in order to prevent progression to active disease. Historically, detection of LTBI has been done using the tuberculin skin test (TST). The TST has certain limitations, however, including subjective interpretation, limited sensitivity in immunosuppressed patients, and the possibility of false-positive results in individuals who have received the BCG vaccine or are infected with other mycobacteria.

 

The QuantiFERON-TB Gold Plus (QFT-Plus) test is an interferon (IFN)-gamma release assay (IGRA) that assesses the cell-mediated immune response to 2 Mycobacterium tuberculosis complex antigens, ESAT-6 and CFP-10, by measuring IFN-gamma levels in plasma. These 2 proteins are absent from all BCG strains and from most nontuberculosis mycobacteria with the exception of Mycobacterium kansasii, Mycobacterium szulgai, and Mycobacterium marinum. Individuals infected with M tuberculosis complex agents, including M tuberculosis, Mycobacterium bovis, Mycobacterium africanum, Mycobacterium microti, Mycobacterium caprae, and Mycobacterium canetti, usually have lymphocytes in their blood that recognize these specific antigens, and this recognition leads to the generation and secretion of IFN-gamma. This cytokine is subsequently detected and quantified using an IFN-gamma enzyme-linked immunosorbent assay.

 

In an M tuberculosis infection, CD4+ T cells play a critical role in immunological control through secretion of IFN-gamma. The prior version of the QFT-Plus assay, the QuantiFERON-TB Gold In-Tube (QFT-Gold) assay, only detected IFN-gamma secreted from CD4+ T cells. Evidence now supports a role for CD8+ T cells in host defense against M tuberculosis infection by likewise producing IFN-gamma, but also by stimulating macrophages to suppress the growth of M tuberculosis, to kill infected cells, and to directly lyse intracellular M tuberculosis bacteria. IFN-gamma-producing M tuberculosis specific CD8+ T cells have been detected in subjects with LTBI and in patients with active TB. ESAT-6 and CFP-10 specific CD8+ T cells have also been frequently described in patients with active tuberculosis (TB) versus patients with LTBI and have been detected in HIV-positive patients and children with TB disease.

 

The QFT-Plus assay has 2 distinct TB antigen tubes: TB Antigen Tube 1 (TB1) and TB Antigen Tube 2 (TB2). Both tubes contain peptide antigens from ESAT-6 and CFP-10 for stimulation of a CD4+ T-cell IFN-gamma response. However, the TB2 tube also contains an additional set of ESAT-6 and CFP-10 peptides specifically designed to stimulate a CD8+ T-cell response.

 

For the most up-to-date information regarding use of IGRAs, refer to the most recent guidelines on the Diagnosis of Tuberculosis in Adults and Children from the American Thoracic Society, the Infectious Diseases Society of America, the Centers for Disease Control and Prevention.(1)

Reference Values

Negative

Day(s) Performed

Monday through Friday

Report Available

2 to 5 days

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Test Classification

This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.

CPT Code Information

86480

Forms

If not ordering electronically, complete, print, and send 1 of the following forms with the specimen:

-General Request (T239)

-Infectious Disease Serology Test Request (T916)

-Microbiology Test Request (T244)