Test Code IETG Interference Evaluation Heterophile, Thyroglobulin Tumor Marker, Serum
Ordering Guidance
If interference or heterophile testing is not required, order HTG2 / Thyroglobulin, Tumor Marker, Serum.
For fine-needle aspirate specimens, order TFNAB / Thyroglobulin, Tumor Marker, Fine-Needle Aspiration Biopsy Needle Wash.
Specimen Required
Patient Preparation: For 12 hours before specimen collection do not take multivitamins or dietary supplements containing biotin (vitamin B7), which is commonly found in hair, skin, and nail supplements and multivitamins.
Collection Container/Tube: Red top (serum gel/SST are not acceptable)
Submission Container/Tube: Plastic vial
Specimen Volume: 2.5 mL
Collection Instructions: Centrifuge and aliquot serum into a plastic vial.
Useful For
Evaluation of suspected interference from heterophile antibodies causing a falsely elevated thyroglobulin result
Profile Information
Test ID | Reporting Name | Available Separately | Always Performed |
---|---|---|---|
TGII | TG, Interference Interpretation | No | Yes |
TGQN | Thyroglobulin, Tumor Marker, S | Yes, (Order HTG2) | Yes |
TGABI | Thyroglobulin Antibody, S | Yes, (Order HTG2) | Yes |
TGMS | Thyroglobulin, Mass Spec., S | Yes | Yes |
Method Name
TGQN/TGABI: Immunoenzymatic Assay
TGMS: Tryptic Protein Fragmentation, purified with Immunocapture, Analysis by Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS)
(This service is performed pursuant to an agreement with SISCAPA Assay Technologies Inc. covering US Patent 7,632,686)
TGII: Medical Interpretation
Reporting Name
Interference Eval, Heterophile, TGSpecimen Type
Serum RedSpecimen Minimum Volume
2 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum Red | Refrigerated (preferred) | 7 days | |
Frozen | 30 days | ||
Ambient | 72 hours |
Reject Due To
Gross hemolysis | Reject |
Gross lipemia | OK |
Gross icterus | Reject |
Clinical Information
Serum thyroglobulin (Tg) measurements are used in the follow-up of differentiated follicular cell-derived thyroid carcinoma. Because Tg is thyroid specific, serum Tg concentrations should be undetectable or very low after the thyroid gland is removed during treatment for thyroid cancer.
Most often Tg is measured by immunometric assays as they are widely available in automated high-throughput instruments, have shorter turnaround times, and have functional sensitivities of 0.1 mcg/L or less. However, these immunoassays may be affected by the presence of both anti-thyroglobulin antibody (TgAb) and heterophile antibody interferences. The presence of TgAb might cause falsely low/undetectable Tg that can mask disease; whereas heterophile antibodies might cause falsely high Tg that can be mistaken for residual or recurrent disease.
Some patients, due to exposure to animal antigens, have developed heterophile antibodies, such as human anti-mouse antibodies, that can interfere with immunoassay testing by binding to the animal antibodies used in immunoassays. In some sandwich immunoassays, including those for Tg, the presence of heterophile antibodies in the patient's sample might lead to a false-positive result.
Although rare, false-negative assay results due to heterophile interference have also been reported in the literature. Manufacturers often add blocking agents to their reagents, but, occasionally, patient samples containing heterophile antibodies are incompletely blocked and exhibit heterophile antibody interference. Subsequent reporting of erroneous results can have adverse effects on patient management, especially with tumor marker assays.
Dilution of the specimen prior to assay performance often yields unexpected nonlinear results in the presence of interfering substances such as heterophile antibodies and/or TgAb. Heterophile blocking tube treatment is also utilized for troubleshooting samples that exhibit potential heterophile interference. Finally, assessment of an analyte such as Tg with an alternative assay will often lead to apparent discrepant results in the presence of heterophile antibodies and/or TgAb interference.
Measurement of Tg by liquid chromatography-tandem mass spectrometry (Tg-MS) has been introduced as a method for accurate Tg quantitation in the presence of TgAb and heterophile antibodies. Tg-MS assays are based on peptide quantitation after tryptic digestion and immunocapture of Tg-specific peptides. The advantage of trypsin digestion is that all proteins are cleaved, including both TgAb and heterophile antibodies, thus eliminating them as interferences.
Reference Values
THYROGLOBULIN TUMOR MARKER
Athyrotic: <0.1 ng/Ml
Intact thyroid: ≤33 ng/mL
THYROGLOBULIN, MASS SPECTROMETRY
Athyrotic: <0.2 ng/mL
Healthy individuals with intact, functioning thyroid: ≤33 ng/mL
THYROGLOBULIN ANTIBODY
<1.8 IU/mL
Reference values apply to all ages.
Day(s) Performed
Monday through Saturday
Report Available
3 to 6 daysPerforming Laboratory
Mayo Clinic Laboratories in RochesterTest Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.CPT Code Information
84432
86800
84432