Test Code CUS1 Copper, Serum


Specimen Required


Patient Preparation: High concentrations of gadolinium, iodine, and barium are known to interfere with most metal tests. If gadolinium-, iodine, or barium-containing contrast media has been administered, the specimen should not be collected for at least 96 hours.

Supplies:

-Metal Free Specimen Vial (T173)

-Metal Free B-D Tube (No Additive), 6 mL (T184)

Collection Container/Tube: 6-mL Plain, royal blue-top Vacutainer plastic trace element blood collection tube

Submission Container/Tube: 7-mL Metal-free, screw-capped, polypropylene vial

Specimen Volume: 0.8 mL

Collection Instructions:

1. Allow the specimen to clot for 30 minutes; then centrifuge the specimen to separate serum from the cellular fraction.

2. Remove the stopper. Carefully pour specimen into metal-free, polypropylene vial, avoiding transfer of the cellular components of blood. Do not insert a pipet into the serum to accomplish transfer, and do not ream the specimen with a wooden stick to assist with serum transfer.

3. See Metals Analysis Specimen Collection and Transport for complete instructions.


Useful For

Diagnosis of:

-Wilson disease

-Primary biliary cholangitis

-Primary sclerosing cholangitis

Method Name

Dynamic Reaction Cell-Inductively Coupled Plasma-Mass Spectrometry (DRC-ICP-MS)

Reporting Name

Copper, S

Specimen Type

Serum

Specimen Minimum Volume

0.2 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Serum Refrigerated (preferred) 28 days METAL FREE
  Ambient  28 days METAL FREE
  Frozen  28 days METAL FREE

Reject Due To

Gross hemolysis OK
Gross lipemia OK
Gross icterus OK

Clinical Information

Copper (Cu) is an important trace element that is associated with a number of metalloproteins. Copper in biological material is complexed with proteins, peptides, and other organic ligands. Up to 90% of copper exported from the liver into peripheral blood is protein bound to ceruloplasmin, transcuprein, or metallothionein. A smaller amount of copper in plasma (<10%) is bound to albumin by specific peptide sequences, and this copper is in equilibrium with plasma amino acids. The ceruloplasmin molecule contains 6 to 8 atoms of Cu per molecule with 6 atoms of Cu involved in the protein's ferroxidase and free radical scavenging activities. The other 1 to 2 atoms of Cu are termed "labile" and may allow ceruloplasmin to act as a copper transporter, with a pool of copper being exchanged between albumin, transcuprein, and the labile sites of ceruloplasmin.

 

Low serum copper, most often due to excess iron or zinc ingestion and infrequently due to dietary copper deficit, results in severe derangement in growth and impaired erythropoiesis. Low serum copper is also observed in hepatolenticular degeneration (Wilson disease) due to a decrease in the synthesis of ceruloplasmin and allelic variances in cellular metal ion transporters. In Wilson disease, the albumin-bound copper may actually be increased, but ceruloplasmin-bound copper is low, resulting in low serum copper. However, during the acute phase of Wilson disease (fulminant hepatic failure), ceruloplasmin and copper levels may be normal; in this circumstance, hepatic inflammation causes increased release of ceruloplasmin. It is useful to relate the degree of liver inflammation to the ceruloplasmin and copper-see discussion on hypercupremia below. Significant hepatic inflammation with normal ceruloplasmin and copper suggest acute Wilson disease.

 

Other disorders associated with decreased serum copper concentrations include malnutrition, hypoproteinemia, malabsorption, nephrotic syndrome, Menkes disease, copper toxicity, and megadosing of zinc-containing vitamins (zinc interferes with normal copper absorption from the gastrointestinal [GI] tract).

 

Hypercupremia is found in primary biliary cholangitis (formerly primary biliary cirrhosis), primary sclerosing cholangitis, hemochromatosis, malignant diseases (including leukemia), thyrotoxicosis, and various infections. Serum copper concentrations are also elevated in patients taking contraceptives or estrogens and during pregnancy.

 

Since the GI tract effectively excludes excess copper, it is the GI tract that is most affected by copper ingestion. Increased serum concentration does not, by itself, indicate copper toxicity.

Reference Values

0-2 months: 40-140 mcg/dL

3-6 months: 40-160 mcg/dL

7-9 months: 40-170 mcg/dL

10-12 months: 80-170 mcg/dL

13 months-10 years: 80-180 mcg/dL

11-17 years: 75-145 mcg/dL

Males:

≥18 years: 73-129 mcg/dL

Females:

≥18 years: 77-206 mcg/dL

Day(s) Performed

Monday through Saturday

Report Available

1 to 3 days

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Test Classification

This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.

CPT Code Information

82525

Forms

If not ordering electronically, complete, print, and send 1 of the following with the specimen:

-General Test Request (T239)

-Gastroenterology and Hepatology Test Request (T728)

-Biochemical Genetics Test Request (T798