Sign in →

Test Code T821Q RUNX1-RUNX1T1 Translocation (8;21), Minimal Residual Disease Monitoring, Quantitative, Varies


Shipping Instructions


1. Refrigerated specimens must arrive within 5 days of collection, and ambient specimens must arrive within 3 days of collection.

2. Collect and package specimen as close to shipping time as possible.



Necessary Information


The following information is required:

1. Pertinent clinical history

2. Date of collection

3. Specimen source (blood or bone marrow)



Specimen Required


Submit only 1 of the following specimens:

 

Specimen Type: Blood

Container/Tube: Lavender top (EDTA) or yellow top (ACD-B)

Specimen Volume: 10 mL

Collection Instructions:

1. Invert several times to mix blood.

2. Send whole blood specimen in original tube. Do not aliquot.

3. Label specimen as blood.

 

Specimen Type: Bone marrow aspirate

Container/Tube: Lavender top (EDTA) or yellow top (ACD-B)

Specimen Volume: 4 mL

Collection Instructions:

1. Invert several times to mix bone marrow.

2. Send bone marrow specimen in original tube. Do not aliquot.

3. Label specimen as bone marrow.


Forms

1. Hematopathology Patient Information (T676)

2. If not ordering electronically, complete, print, and send an Hematopathology/Cytogenetics Test Request (T726) with the specimen.

Useful For

Detection of RUNX1-RUNX1T1 gene fusion in acute myeloid leukemia patients at the time of diagnosis

 

Minimal residual disease monitoring during the clinical and therapeutic course of these patients

Method Name

Quantitative Real-Time Reverse Transcription Polymerase Chain Reaction (qRT-PCR)

Reporting Name

RUNX1/RUNX1T1, t(8;21), Quant, V

Specimen Type

Varies

Specimen Minimum Volume

Peripheral blood: 8 mL
Bone marrow: 2 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Varies Refrigerated (preferred) 5 days
  Ambient  72 hours

Reject Due To

Gross hemolysis Reject
Bone marrow core biopsies
Heparin sample
Paraffin-embedded bone marrow clots
Slides
Paraffin shavings
Moderately to severely clotted
Reject

Clinical Information

RUNX1-RUNX1T1 minimal residual disease (MRD) monitoring in patients with acute myeloid leukemia (AML) with translocation t(8;21)(q22;q22) is useful for evaluating disease response after therapy and identifying individuals with increased risk of relapse. Quantitative real-time reverse transcription polymerase chain reaction testing in neoplasms with known clonal genetic markers can achieve highly sensitive detection of neoplastic cells in blood or bone marrow samples. It is one of the most mature technologies available for this purpose. In this assay, translocation of chromosome 8q22 to 21q22 resulting in fusion of two genes RUNX1 and RUNX1T1 will be evaluated. Quantitative results will provide physicians with an accurate and precise measurement of disease burden to guide patient intervention decisions. This assay can be used for post-therapy MRD monitoring as well as detection of RUNX1-RUNX1T1 fusion in AML patients at the time of diagnosis.

Reference Values

An interpretive report will be provided.

Day(s) Performed

Monday through Saturday

Report Available

4 to 8 days

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Test Classification

This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.

CPT Code Information

81401