Test Code RBR Retinol-Binding Protein, Random, Urine
Specimen Required
Container/Tube: Plastic, 5-mL tube
Specimen Volume: 5 mL
Collection Instructions:
1. Collect a random urine specimen.
2. No preservative.
Useful For
Assessing renal tubular injury or dysfunction using random urine collections
Screening for other tubular abnormalities
Detecting chronic asymptomatic renal tubular dysfunction.(2)
Profile Information
Test ID | Reporting Name | Available Separately | Always Performed |
---|---|---|---|
CRETR | Creatinine, Random, U | Yes, (Order RCTUR) | Yes |
RBPR | Retinol-Binding Protein, Random, U | No | Yes |
Method Name
CRETR: Enzymatic Colorimetric Assay
RBPR: Immunonephelometry
Reporting Name
Retinol-Binding Protein, Random, USpecimen Type
UrineSpecimen Minimum Volume
1 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Urine | Refrigerated (preferred) | 7 days | |
Frozen | 7 days |
Reject Due To
All specimens will be evaluated at Mayo Clinic Laboratories for test suitability.Clinical Information
Retinol-binding protein is a low-molecular-weight protein of 21 kDa that transports retinol (vitamin A alcohol) from the liver to peripheral tissues.(1) Retinol-binding protein is most often found bound to transthyretin, but a small, unbound fraction (<10%) passes freely through glomerular membranes and is reabsorbed by renal proximal tubules cells where it is catabolized. Due to extensive tubular reabsorption, under normal conditions very little of the filtered retinol-binding protein appears in the final excreted urine. Therefore, an increase in the urinary excretion of retinol-binding protein indicates proximal tubule injury and/or impaired proximal tubular function.(1) Measurement of retinol-binding protein in urine is, therefore, a useful aid in the monitoring and/or diagnosis of kidney disease.
Elevated excretion rates can indicate tubular damage associated with renal tubulointerstitial nephritis or tubular toxicity from heavy metal or nephrotoxic drug exposure. Glomerulonephropathies and renal vasculopathies also are often associated with coexisting tubular injury and so may result in elevated retinol-binding protein excretion. Measurement of urinary excretion of alpha-1-microglobulin, another low-molecular-weight protein, is an alternative to the measurement of retinol-binding protein. To date, there are no convincing studies to indicate that one test has better clinical utility than the other.
Urinary excretion of retinol-binding protein can be determined from either a 24-hour collection or from a random urine collection. The 24-hour collection is traditionally considered the gold standard. For random or spot collections, the concentration of retinol-binding protein is divided by the urinary creatinine concentration. This corrected value adjusts retinol-binding protein for variabilities in urine concentration.
Reference Values
≥18 years: <190 mcg/g creatinine
Reference values have not been established for patients that are less than 18 years.
Day(s) Performed
Monday, Wednesday, Friday
Report Available
1 to 4 daysPerforming Laboratory
Mayo Clinic Laboratories in RochesterTest Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.CPT Code Information
83883-Retinol -Binding Protein, Random, U