Test Code PLA2I Phospholipase A2 Receptor, Immunofluorescence, Serum
Ordering Guidance
This test can be used in a complementary fashion with a quantitative enzyme-linked immunosorbent assay to confirm a positive result, especially if it is a low-level titer. Since the immunofluorescence is more sensitive, it can also be used to detect or follow patients with low level antibodies not detected by ELISA. Â
Specimen Required
Supplies: Sarstedt Aliquot Tube 5 mL (T914)
Collection Container/Tube:
Preferred: Serum gel
Acceptable: Red top
Submission Container/Tube: Plastic vial
Specimen Volume: 1 mL
Collection Instructions: Centrifuge and aliquot serum into a plastic vial within 2 hours of collection.
Useful For
Distinguishing primary from secondary membranous nephropathy in patients with low levels of anti-phospholipase A2 receptor (PLA2R) antibodies
Screening for anti-PLA2R antibodies
Monitoring patients with membranous nephropathy at very low antibody titers
Method Name
Indirect Immunofluorescence Assay (IFA)
Reporting Name
PLA2R, Immunofluorescence, SSpecimen Type
SerumSpecimen Minimum Volume
0.5 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum | Refrigerated (preferred) | 14 days | |
Frozen | 14 days | ||
Ambient | 8 hours |
Reject Due To
Gross hemolysis | Reject |
Gross lipemia | OK |
Clinical Information
Membranous nephropathy (MN) is a rare disease in which immune complexes deposit at the glomerular basement membrane, causing damage to the filtration barrier, resulting in proteinuria. Recent studies have shown that in approximately 70% of patients with primary MN (pMN), the immune complexes consist of autoantibodies against the podocyte protein M-type phospholipase A2 receptor (PLA2R).(1) There is also evidence that levels of anti-PLA2R autoantibodies correlate well with disease activity and progression.(2) The presence of anti-PLA2R antibodies could also potentially be used to differentiate pMN from other causes of nephrotic syndrome if a biopsy is not possible. Among patients with chronic kidney disease (CKD) awaiting kidney transplantation, higher levels of anti-PLA2R could predict those more likely to recur after transplantation.(2) Mayo Clinic Laboratory data suggest that there is a high concordance between the enzyme-linked immunosorbent assay and indirect immunofluorescence assay (IFA) PLA2R results, although the IFA may be more sensitive in monitoring patients with membranous nephropathy with very low antibody titers.
Reference Values
Negative
Day(s) Performed
Monday, Wednesday, Friday
Report Available
3 to 7 daysPerforming Laboratory
Mayo Clinic Laboratories in RochesterTest Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.CPT Code Information
86255
Forms
If not ordering electronically, complete, print, and send a Renal Diagnostics Test Request (T830) with the specimen.