Sign in →

Test Code HICSF Histoplasma Antibody Complement Fixation and Immunodiffusion, Spinal Fluid


Ordering Guidance


This test should be ordered if patient is seropositive for Histoplasma antibodies in serum.



Specimen Required


Container/Tube: Sterile vial

Specimen Volume: 1 mL

Collection Instructions: Submit specimen from collection vial 1.


Useful For

Aiding in the diagnosis of Histoplasma meningitis using spinal fluid specimens

Method Name

Complement Fixation (CF)/Immunodiffusion (ID)

Reporting Name

Histoplasma Ab CompFix/ImmDiff, CSF

Specimen Type

CSF

Specimen Minimum Volume

0.8 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
CSF Refrigerated (preferred) 14 days
  Frozen  14 days

Reject Due To

Gross hemolysis OK
Gross lipemia OK

Clinical Information

Histoplasma capsulatum is a dimorphic fungus endemic to the Midwestern United States, particularly along the Mississippi River and Ohio River valleys. Infection occurs following inhalation of fungal microconidia, and subsequent clinical manifestations are largely dependent on the fungal burden at the time of exposure and the patient's underlying immune status. While the vast majority (>90%) of exposed individuals will remain asymptomatic, individuals seeking medical attention can present with a diverse set of symptoms ranging from a self-limited pulmonary illness to severe, disseminated disease. Individuals at risk for severe infection include those with impaired cellular immunity, who have undergone organ transplantation, who are HIV positive, or who have a hematologic malignancy.

 

The available laboratory methods for the diagnosis of H capsulatum infection include fungal culture, molecular techniques, serologic testing, and antigen detection. While culture remains the gold standard diagnostic test and is highly specific, prolonged incubation is often required, and sensitivity decreases (9%-34%) in cases of acute or localized disease. Similarly, molecular methods offer high specificity but decreased sensitivity. Serologic testing likewise offers high specificity; however, results may be falsely negative in immunosuppressed patients or those who present with acute disease. Also, antibodies may persist for years following disease resolution, thereby limiting the clinical specificity.

Reference Values

Anti-Yeast Antibody by Complement Fixation

Negative (positive results reported as titer)

 

Antibody by Immunodiffusion

Negative (positive results reported as band present)

Day(s) Performed

Monday through Friday

Report Available

3 to 7 days

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Test Classification

This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.

CPT Code Information

86698 x2