Sign in →

Test Code FHSPL Histamine Plasma


Specimen Required


Specimen Type: Plasma

Collection Container/Tube: Lavender top (EDTA)

Submission Container/Tube: Plastic vial

Specimen Volume: 3 mL

 

Collection Instructions:

Draw 3 mL blood in a lavender-top (EDTA) tube(s). Cool immediately on ice. Centrifuge at 1500 rpm for 10 minutes at 4° C. The centrifugation should be performed within 20 minutes of collection. Carefully remove 1 mL of EDTA plasma from the upper part of the tube. Freeze and send frozen in a plastic vial.


Method Name

Enzyme Immunoassay (EIA)

Reporting Name

Histamine Plasma

Specimen Type

Plasma EDTA

Specimen Minimum Volume

1 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Plasma EDTA Frozen 28 days

Reject Due To

Gross Hemolysis Reject
Gross Lipemia Reject
Other Specimens other than Plasma EDTA. Test is strict frozen

Reference Values

<1.0 ng/mL

Day(s) Performed

Monday, Tuesday, Thursday

Report Available

2 to 7 days

Performing Laboratory

Eurofins Viracor

Test Classification

This test was developed and its performance characteristics determined by Viracor Eurofins. It has not been cleared or approved by the U.S. Food and Drug Administration.

CPT Code Information

83088