Test Code FANTI Anti-IgE
Specimen Required
Specimen Type: Serum
Container/Tube: Red Top
Specimen Volume: 1.0 mL
Collection Instructions: Draw blood in a plain red-top tube(s), serum gel tube(s) is acceptable. Spin down and send 1.0 mL of serum ambient in a plastic vial.
Method Name
ELISA
Reporting Name
Anti-IgESpecimen Type
SerumSpecimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum | Ambient (preferred) | 7 days | |
Frozen | 28 days | ||
Refrigerated | 7 days |
Reject Due To
Gross hemolysis | Reject |
Gross lipemia | Reject |
Gross icterus | Reject |
Reference Values
Normal
Day(s) Performed
Wednesday
Report Available
7 to 11 daysPerforming Laboratory
Eurofins ViracorCPT Code Information
83516
Specimen Minimum Volume
0.5 mL
Clinical Information
This ELISA measures IgG antibodies specific for IgE. A result of normal indicates that the level of IgG anti-IgE antibodies is similar to that seen in a population of healthy individuals. A result of elevated indicates an increased level of IgG anti-IgE antibodies compared to healthy individuals. These autoantibodies have been implicated as a causative agent in autoimmune chronic urticaria and atopic dermatitis.