Sign in →

Test Code PCPUG Phencyclidine (PCP), Confirmation, serum

Reporting Name

Phencyclidine (PCP), Serum

Performing Laboratory

Medtox Laboratories, Inc.

Specimen Type

Varies


Specimen Required


Submit only 1 of the following specimens:

 

Serum

Draw blood in a plain red-top tube(s), serum gel tube is not acceptable. Spin down and send 5 mL of serum refrigerated in a plastic vial.

 

Plasma

Draw blood in a green-top (sodium heparin) tube(s), plasma gel tube is not acceptable. Spin down and send 5 mL sodium heparin plasma refrigerated in a plastic vial.

 


Specimen Minimum Volume

2 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Varies Refrigerated (preferred) 14 days
  Frozen  180 days

Reject Due To

Hemolysis NA
Lipemia NA
Icterus NA
Other NA

Reference Values

Toxic:  Greater than 100 ng/mL

Serious Toxicities likely:  Greater than 300 ng/mL

Day(s) Performed

Monday through Sunday

CPT Code Information

83992

Report Available

5 to 9 days

Method Name

Gas Chromatography-Mass Spectrometry (GC-MS)